View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 511) |
Meteor
Series
Models: 204
(2.5") 304 (3.5") 504 (4.5") 604 (5.5")
|
-
UL Recognition
-
Taut Band Mechanism standard
-
Thermoplastic Case and Window
-
Three choices of mounting: lens, surface or
bezel
-
Proven reliability - accurate measurement &
display
-
Wide selection of Ranges
-
Customized Scales available
The Meteor Series features a taut
band suspension which provides friction-free measurements for the
ultimate in accuracy while allowing the meter to respond to
extremely small signals. Taut band meters also offer increased
resistance to shock and vibration.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (750 x 600) |
7000
Series
Models: 7025
(2.5") 7035 (3.5") 7045 (4.5") 7055 (5.5")
|
-
UL Recognition
-
Removable Scales
-
Taut Band Mechanism standard
-
Phenolic Fronts
-
Glass Windows
-
Three choices of mounting: lens, surface or
bezel
-
Proven reliability - accurate measurement &
display
-
Wide selection of Ranges
-
Optional illumination
-
Customized Scales available
The 7000 Series meters provide quick-change
versatility. Many different variables can be measured on one
meter by simply switching the meter's scale and using a different
multiplier or shunt compatible with the new scale. A few basic
ranges and a supply of interchangeable dials make the 7000 Series
an inexpensive equivalent of many single meters.
|
 |
View Catalog Page (PDF Format)
Download Manual (ZIP format)
< Click Image to Enlarge (744 x 600) |
Black
Panelist
Models: 303
(3.5") 503 (4.5") 603 (5.5")
|
-
Rugged Phenolic Case
-
Thick Glass Window
-
Wide selection of Ranges
-
Customized Scales available
A rugged case and thick glass window
make the black Phenolic Panelist suitable for industrial
environments.
|
 |
View Catalog Page (PDF Format)
Download Manual (ZIP format)
< Click Image to Enlarge (746 x 600) |
Clear
Panelist
Models: 202
(2.5") 302 (3.5") 502 (4.5") 602 (5.5")
|
-
Clear plastic Case and Window
-
Front mounting standard
-
Wide selection of Ranges
-
Customized Scales available
The Clear Panelist is popular for
front-mounting applications. It can also be mounted behind the panel
with special
hardware.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click Image
to Enlarge (764 x 600) |
Black
Phenolic Long Scale & Bezel
Models: 426 (4.5") 361 (3.5")
561 (5.5") |
Model 426
-
Long Scale
-
Low profile, thin front
-
Rugged, Stylish Case
-
Customized Scales available
Models: 361,
561
-
Integral Bezel models
-
Built-in illumination window
-
Wide selection of Ranges
-
Customized Scales available
Black Phenolic panel meters are rugged, stylish,
sensitive and accurate. They range in size from 3 1/2" to 5 1/2" and
can be either front or bezel mounted. Their rugged designs are
particularly suitable for use in demanding environments. The Black
Phenolic panel meters have a standard indication accuracy of ±2%
full scale for DC ranges (±3% for AC ranges) and are available with
"Super Calibrated Accuracy" of ±0.5% for exacting measurement
requirements.
The Model 426 is a versatile panel meter with a
low-profile thin front. It has a scale approximately equivalent to
that of a conventional 4 1/2" meter, but the dial area height is the
same as that of a 3 1/2" meter. The Model 426 requires no more panel
space than other meters with shorter scales. Designed so that it is
equally attractive and practical whether mounted in front of a panel
or recessed, the Model 426 has found immediate acceptance in today's
narrow rack panels.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click Image
to Enlarge (703 x 600) |
1000
Series Edgewise
Models: 1015 (1.5") 1025 (2.5") 1035
(3.5") |
-
Stackable mounting
-
Easy dial changing
-
Tough, high temperature polycarbonate
case
-
Optional illuminated dials
-
Vertical or horizontal mounting
-
Wide selection of Ranges
-
Customized Scales available
The 1000 Series Edgewise panel
instruments have been designed to satisfy the demand for an
attractive and accurate analog display in a minimum of panel
space.
A novel case design permits
snap-together access to the dial and mechanism for convenient
dial changing. The case itself - clear front window and black
case - is molded from high impact polycarbonate.
The unique flat d'Arsonval mechanism
with pivot-and-jewel suspension provides 2% accuracy with either
vertical or horizontal mounting. Unsurpassed stability makes
frequent zero adjusting unnecessary. The Models 1015 and 1025
have rear zero adjustment while the Model 1035 features a unique
front adjustment.
Panel mounting has been simplified
in the 1000 Series. Two mounting clips are attached without
screws to the meter case after it has been inserted through its
panel cutout. The clips are then tightened against the
panel.
|
 |
View Catalog Page
(PDF Format) Download
Manual (ZIP format)
< Click Image
to Enlarge (750 x 600) |
Edgewise Model:
371 (3.5") |
-
All ranges are taut band
-
Front zero adjustment
-
Horizontal or vertical scale
-
Anti-parallax stepped scale for AC & DC
ranges
-
Mirrored scale on pyrometer ranges
The Model 371 was designed for
applications where panel space is limited. The Model 371 can be
mounted either horizontally or vertically . . . it is also
stackable. Two or more units can be mounted side-by-side with no
panel space between the dials, allowing for easy comparison of
several variables.
The Model 371 panel meters have a
shielded meter mechanism which allows them to be mounted on
either magnetic or non-magnetic panels.
|
 |
View Catalog Page (PDF Format)
Download Manual (ZIP format)
< Click Image to Enlarge (741 x 600) |
Round Model: 1235
(2.5") |
-
Polycarbonate case and window
-
Molded matte finish
-
Tough, high temperature polycarbonate case
-
Bold lettering and scale arcs that provide clean
crisp readability
-
Self-shielding mechanism for mounting on either
magnetic or non-magnetic panels
-
Wide selection of Ranges
Options :
-
Glass Window s 1/4" terminal spacing
-
Pivot-and-Jewel mechanisms
-
Special accuracy and tracking specs
-
Customized scales
-
Mirrored scales
-
Special ballistic response
-
Temperature compensation
-
Special resistance
The versatile Model 1235 3 1/2"
round panel meter has been designed for cost effectiveness while
maintaining the quality that has made
LFE/api a leader in the test and
measurement marketplace. The Model 1235 is available in AC , DC,
Pyrometer and Process Control Ranges. Special ranges and options
are available to meet your instrumentation
requirements.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click Image
to Enlarge (388x 385) |
Round
Ruggedized-Sealed
Models: 255 (2.5") 355 (3.5") 455
(4.5") |
-
Gasket-sealed metal case
-
Great in severe environments
-
Taut band suspension standard for sensitive
ranges
-
Standard indication accuracy of ±3% for
AC
-
Wide selection of Ranges
-
Customized scales available
-
Mirrored scales available on Model 455
-
Special pointers and other options also
available
Ruggedized-sealed panel meters are
designed and built to function in severe environments. The meter
movement is securely anchored in a gasket-sealed metal case to
provide protection against severe shock, salt spray, fungus and
corrosive chemicals. The meter conforms to the gasket-sealing
requirements of the MIL-M-10204-C specifications. The
ruggedized-sealed panel meters are available in three sizes: 2
1/2", 3 1/2" and 4 1/2" diameters. These panel meters are
identical in appearance and in dimensions with the other
LFE/api ruggedized-sealed instruments
(pyrometers and meter relays). This interchangeability
facilitates panel designing and functional upgrading.
The ruggedized-sealed panel meters
use d'Arsonval meter mechanisms. The meters are furnished with
taut band suspensions as standard in the sensitive ranges from 0-
5mA to 100mA and 0-5mV to 0-25mV. Taut band suspensions may be
specified for other ranges as required. The higher ranges are
normally furnished as pivot-and-jewel mechanisms. Taut bands
provide the advantage of friction-free measurements for the
ultimate in accuracy. Taut bands also allow the meter to respond
to extremely small signals, extending the application of
ruggedized- sealed panel meters to areas of sensitivity not
previously possible. Additionally, taut band meters offer
increased resistance to shock and vibration over older pivot-and
jewel designs. Because severe vibration can cause momentary
erratic readings on taut band meters, Triplett can provide
specially damped meters which are free of this problem, but have
relatively slow response times. LFE/api ruggedized-sealed panel
meters have a one year warranty.
|
 |
View
Catalog Page (PDF Format) Download
Manual (ZIP format)
< Click Image
to Enlarge (706 x 600) |
Optical Meter-Relay Control Module 196
Series
Models: 1963
(3.5") 1964 (4.5") 1965 (3.5") 1966 (4.5")
1967 (4.5") |
-
Modern rectangular appearance
-
Plug-in control module
-
Proven optical setpoints
-
Available with mounting bezels (Models 1965 &
1966)
-
Limit lights & manual reset switches optional
(Model 1967)
The 196 Series Meter-Relays contain
an exclusive light sensitive transistor switch that provides the
ultimate in control simplicity and reliability. This switch
controls the load relays. There are no pointer contacts or
mechanical interference in the meter mechanism. The controllers
are supplied with a plug-in control module that mounts directly
on the rear of the Meter-Relay or may be remotely mounted with an
accessory cable.
(see PDF document for additional
specifications)
Meter Relay Specifications
*
- On-Off or Alarm Control :
- Each Meter-Relay is engineered for
On-Off (automatic reset) control action. For alarm latching
(manual reset), simply remove jumper wire from terminals at
rear of control module and substitute a normally open
momentary switch.
- 117 Volt AC operation :
- No special power supply needed . . .
simply connect to 117 volt, 50 or 60Hz source
- Long Lamp Life :
- Because the lamp is operated at well
below rated voltage, life expectancy is conservatively
rated at 5 years (typical).
- Safe Operation :
- In the event of component failure or
loss of control power, energized setpoint relays
immediately de-energize.
- Control Mounting Module :
- Rear mount standard. May be remotely
mounted using accessory kit.
- Setpoint Coincidence :
- +/- 2% of full scale at 117VAC input
power (maximum difference in indications of setpointer and
indicating pointer when control action occurs.
- Repeatability :
- 0.3 percent of full scale
- Setpointer Travel :
- 100 percent of full scale travel: double
setpointers can be positioned to within 2 mechanical
degrees of each other - approximately 2.2% of full
scale.
- Minimum Span :
- Input Power :
- 117VAC +/- 10% , 50/60Hz. 7.0 Volt
Amperes maximum
- Load Relay :
- Contact Rating :
- 5 Amperes AC non-inductive at 120 Volts
- 5 Amperes DC non-inductive at 28 Volts
- 0.2 Amperes DC non-inductive at 125
Volts
* Except as
noted, the above specifications cover the meter-relay function
only - i.e., all values given for accuracy, repeatability, etc.,
are exclusive of basic meter performance.
|
 |
View
Catalog Page (PDF Format) Download
Manual (ZIP format)
< Click
Image to Enlarge (755 x 600) |
Optical Meter-Relay Control Module 195
Series
Models: 1953
(3.5") 1954 (4.5") |
-
Plug-in control module
-
Long life lamp operation
-
Plastic front and base
-
Proven optical setpoints
-
On/Off or alarm control
The 195 Series Meter-Relays contain an
exclusive light sensitive transistor switch that provides the
ultimate in control simplicity and reliability. This switch
controls the load relays. There are no pointer contacts or
mechanical interference in the meter mechanism. The controllers
are supplied with a plug-in control module that mounts directly
on the rear of the Meter-Relay or may be remotely mounted with
an accessory cable.
Meter Relay Specifications
*
- On-Off or Alarm Control :
- Each Meter-Relay is engineered for
On-Off (automatic reset) control action. For alarm
latching (manual reset), simply remove jumper wire from
terminals at rear of control module and substitute a
normally open momentary switch.
- 117 Volt AC operation :
- No special power supply needed . . .
simply connect to 117 volt, 50 or 60Hz source
- Long Lamp Life :
- Because the lamp is operated at well
below rated voltage, life expectancy is conservatively
rated at 5 years (typical).
- Safe Operation :
- In the event of component failure or
loss of control power, energized setpoint relays
immediately de-energize.
- Control Mounting Module :
- Rear mount standard. May be remotely
mounted using accessory kit.
- Setpoint Coincidence :
- +/- 2% of full scale at 117VAC input
power (maximum difference in indications of setpointer
and indicating pointer when control action
occurs.
- Repeatability :
- 0.3 percent of full scale
- Setpointer Travel :
- 100 percent of full scale travel:
double setpointers can be positioned to within 2
mechanical degrees of each other - approximately 2.2% of
full scale.
- Minimum Span :
- Input Power :
- 117VAC +/- 10% , 50/60Hz. 7.0 Volt
Amperes maximum
- Load Relay :
- Contact Rating :
- 5 Amperes AC non-inductive at 120
Volts
- 5 Amperes DC non-inductive at 28
Volts
- 0.2 Amperes DC non-inductive at 125
Volts
* Except as
noted, the above specifications cover the meter-relay function
only - i.e., all values given for accuracy, repeatability, etc.,
are exclusive of basic meter performance.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (744 x 600) |
Optical Meter-Relay Self Contained K
Series
Models: 303K
(3.5") 503K (4.5") 603K (5.5")
|
-
UL Recognized with suffix "KU"
-
Temperature & non-temperature models
-
Continuous indication
-
Infinite noise rejection
-
Easy installation - all connections at rear
terminals
-
Solid-state circuitry
-
Single and double setpoints
-
Rectangular & stackable edgewise
models
-
Customized Scales available
Optical Compack Controllers operate on an optical
principle associated with the meter mechanism. A light source
(incandescent lamp) and a photo-resistive cell combination are
positioned by the setpoint mechanism. An opaque vane is attached to
the meter mechanism so that when the indicating pointer reaches the
setpoint the vane intercepts the light from the source, causing a
sharp change in resistance of the photocell. The resistance change
is used to actuate a relay driver circuit for control of an external
load. The response characteristics of D'Arsonval mechanisms
automatically provide filtering of the input signal, making Compack
Controllers immune to line noise and transient surges. Optical type
controllers are the best choice for applications in electrically
noisy environments.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (616 x 600) |
Magnetic Contact Meter-Relay
Model: 202M |
-
Low voltage contact reliability, AC or DC
-
Low cost alarm plus indication
-
Adjustable setpoints
-
Compensated pyrometer models
Options :
-
Custom Dials
-
Super Calibrated Meters (DC Ranges only) Class
I, II, II, & IV
-
Special Resistance
-
Alternate Mounting
-
Special Pyrometers
-
Special Ranges
-
Zero Adjust
Magnetic-contact meter-relays offer the simplest
but still positive control action in the field of electro-mechanical
devices. They are especially suitable for applications where only
low voltage is available across the meter but a reliable contact
must be made and held at setpoint. Usually an alarm is actuated or
an opening mechanism is shut down.
When the moving element contacts of a
magnetic-contact meter-relay close at setpoint, auxiliary contact
pressure is provided by small permanent magnets to ensure a low
resistance contact circuit. Unlocking is accomplished by
mechanically resetting the contacts.
|
 |
View Catalog Page (PDF Format)
Download Manual (ZIP format)
< Click Image to Enlarge (524 x 520) |
Locking Coil Meter Relay Round
Ruggedized
Models:
255C (2.5") 355C (3.5") 455C (4.5")
|
Locking-Coil meter-relays are essentially
d'Arsonval meter mechanisms with setpoint arms and contacts. The
locking coil of the meter-relay is an integral part of the signal
coil and is wound with the signal coil as part of the meter-relay's
moving element. The locking coil is energized when the indicating
pointer reaches the setpoint. Torque produced by the locking current
drives the contacts together and holds them firmly together to
create an excellent low resistance control circuit. The way that
LFE/api locking coil contacts open is
another reason for their consistent performance. The meter relays
are designed so that the contacts open only after the locking coil
circuit has been broken. A small spark is produced when the contacts
"make". This keeps them free from pitting while a wiping motion on
each "make" and "break" keeps them clean.
The LFE/api
locking-coil meter-relay is an extremely simple and stable device to
apply in limit control applications. It indicates as well as
controls. No readout circuitry is needed in the control system, and
precise control with indication is provided at moderate cost. Only
three basic components are required for the system: a high or low
setpoint locking-coil meter-relay, a load relay and a DC power
source. A double setpoint control system is hardly more
complicated; it requires only a
LFE/api double setpoint meter-relay
and an extra load relay.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 586) |
Optical Meter-Relay Black
Panelist (Phenolic) L Series
Models: 303L
(3.5") 503L (4.5") 603L (5.5")
|
-
High, Low or Double setpoints
-
Continuous indication
-
Requires minimum depth behind panel
-
For use with separate control module or user
supplied circuit
-
Smooth vernier control of setpoints
-
Available with either Taut Band or
Pivot-and-Jewel
LFE/api Optical "L"
Meter-Relays provide the most comprehensive range of non-contacting
control and display instruments available today. This meter-relay
uses the same meter and setpoint components supplied in the "K"
Series Meter-Relays except that the meter and the corresponding
control module may be separately mounted allowing the meter portion
to fit in control boxes with shallower depth.
Optical Meter-Relays provide one or two visible
setpoints as well as precise meter indication of the control
variable over the entire scale. Velvet-drive control knobs provide
vernier reduction for precise setpoint adjustment (except on Model
371-L). Double setpoints are controlled by two separate knobs,
eliminating operator confusion.
The low torque instruments are all supplied with
taut band mechanisms standard while the high torque instruments are
normally pivot-and-jewel mechanisms with taut band optional.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 582) |
Optical Meter-Relay Clear Panelist L
Series
Models: 302L
(3.5") 502L (4.5") 602L (5.5")
|
-
High, Low or Double setpoints
-
Continuous indication
-
Requires minimum depth behind panel
-
For use with separate control module or user
supplied circuit
-
Smooth vernier control of setpoints
-
Available with either Taut Band or Pivot-and-Jewel
LFE/api Optical "L"
Meter-Relays provide the most comprehensive range of non-contacting
control and display instruments available today. This meter-relay
uses the same meter and setpoint components supplied in the "K"
Series Meter-Relays except that the meter and the corresponding
control module may be separately mounted allowing the meter portion
to fit in control boxes with shallower depth.
Optical Meter-Relays provide one or two visible
setpoints as well as precise meter indication of the control
variable over the entire scale. Velvet-drive control knobs provide
vernier reduction for precise setpoint adjustment (except on Model
371-L). Double setpoints are controlled by two separate knobs,
eliminating operator confusion.
The low torque instruments are all supplied with
taut band mechanisms standard while the high torque instruments are
normally pivot-and-jewel mechanisms with taut band
optional. |
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format) < Click Image
to Enlarge (800 x 387) |
Remote Meter-Relay Modules B
Series
Models:
901B 903B 905B 907B
|
-
Variety of control functions
-
3 foot cable for connection to
Meter-Relay
-
12, 24 or 28 VDC supply optional
-
DPDT Output Relays optional
Optical meter relays provide a resistance change
at setpoint. Before they can provide a high-level control function,
a control module is required. LFE/api
control modules are available with the following control functions:
On/Off (also used for limit or cycling control applications), time
proportioning relay, SCR phase fired pulse and 3-zone control. The
3-zone control module contains two relay outputs to provide relay
closures when the measurement signal exceeds the limits of the dead
band at a single point.
Modules can be used with single or double
setpoint meter relays for control applications using temperature,
current or voltage sources. Because the module is mounted remotely
from the meter relay, valuable space behind the panel is saved. The
module is connected by plug-in cable to the Optical Meter Relay. The
standard cable length furnished with the module is three feet.
Lengths up to twelve feet are optionally available.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 586) |
Solid-State Setpoint Black
Panelist (Phenolic) P
Series
Models: 303P (3.5") 503P (4.5")
603P (5.5")
|
-
High, Low or Double setpoints
-
Continuous indication
-
Requires minimum depth behind panel
-
Standard Range: 0-1 mADC Pivot-and-Jewel High
Torque (other ranges available)
-
Standard Tracking Tolerance is 1% of Full Scale
Options :
-
Zero right, zero center, zero off-center
-
Optional sensitivities available
-
Linearity (tracking) to 0.5%
-
Accuracy to ±1% of full scale.
-
Custom dials s Black mounting bezel for Model
371-P.
-
Rubber gaskets
These setpoint meters incorporate a special
potentiometer with setpoint arms adjustable over the scale of a
panel meter to provide a good visual comparison of the measured
variable relative to the setpoint. The potentiometer element and the
setpoint wipers are brought out in a small 9-pin connector for easy
connection to the user's external signal conditioning amplifiers and
comparators.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (750 x 600) |
Solid-State Setpoint Edgewise P
Series
Model:
371P
|
-
High, Low or Double setpoints
-
Continuous indication
-
Requires minimum depth behind panel
-
Standard Range: 0-1 mADC Pivot-and-Jewel High
Torque (other ranges available)
-
Standard Tracking Tolerance is 1% of Full
Scale
Options :
-
Zero right, zero center, zero off-center
-
Optional sensitivities available
-
Linearity (tracking) to 0.5% s Accuracy to ±1% of
full scale.
-
Custom dials s Black mounting bezel for Model
371-P.
-
Rubber gaskets
This setpoint meter incorporates a special
potentiometer with setpoint arms adjustable over the scale of a
panel meter to provide a good visual comparison of the measured
variable relative to the setpoint. The potentiometer element and the
setpoint wipers are brought out in a small 9-pin connector for easy
connection to the user's external signal conditioning amplifiers and
comparators.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 586) |
Locking-Coil Meter-Relay Black
Panelist (Phenolic) C Series
Models: 303C
(3.5") 503C (4.5") 603C (5.5")
|
-
Simple contact circuit for limit control
-
No amplifiers required
-
Wide range of models and styles
-
Available to match Analog Panel Meter
Series
Locking-Coil meter-relays are essentially
d'Arsonval meter mechanisms with setpoint arms and contacts. The
locking coil of the meter-relay is an integral part of the signal
coil and is wound with the signal coil as part of the meter-relay's
moving element. The locking coil is energized when the indicating
pointer reaches the setpoint. Torque produced by the locking current
drives the contacts together and holds them firmly together to
create an excellent low resistance control circuit. The way that
LFE/api locking coil contacts open is
another reason for their consistent performance. The meter relays
are designed so that the contacts open only after the locking coil
circuit has been broken. A small spark is produced when the contacts
"make". This keeps them free from pitting while a wiping motion on
each "make" and "break" keeps them clean.
The LFE/api
locking-coil meter-relay is an extremely simple and stable device to
apply in limit control applications. It indicates as well as
controls. No readout circuitry is needed in the control system, and
precise control with indication is provided at moderate cost. Only
three basic components are required for the system: a high or low
setpoint locking-coil meter-relay, a load relay and a DC power
source. A double setpoint control system is hardly more
complicated; it requires only a
LFE/api double setpoint meter-relay
and an extra load relay.
|
 |
View Catalog Page (PDF Format)
Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 582) |
Locking-Coil Meter-Relay Clear Panelist C
Series
Models: 202C
(2.5") 302C (3.5") 502C (4.5") 602C (5.5")
|
-
Simple contact circuit for limit control
-
No amplifiers required
-
Wide range of models and styles
-
Available to match Analog Panel Meter Series
Locking-Coil meter-relays are essentially
d'Arsonval meter mechanisms with setpoint arms and contacts. The
locking coil of the meter-relay is an integral part of the signal
coil and is wound with the signal coil as part of the meter-relay's
moving element. The locking coil is energized when the indicating
pointer reaches the setpoint. Torque produced by the locking current
drives the contacts together and holds them firmly together to
create an excellent low resistance control circuit. The way that
LFE/api locking coil contacts open is
another reason for their consistent performance. The meterrelays are
designed so that the contacts open only after the locking coil
circuit has been broken. A small spark is produced when the contacts
"make". This keeps them free from pitting while a wiping motion on
each "make" and "break" keeps them clean.
The LFE/api
locking-coil meter-relay is an extremely simple and stable device to
apply in limit control applications. It indicates as well as
controls. No readout circuitry is needed in the control system, and
precise control with indication is provided at moderate cost. Only
three basic components are required for the system: a high or low
setpoint locking-coil meter-relay, a load relay and a DC power
source. A double setpoint control system is hardly more
complicated; it requires only a
LFE/api double setpoint meter-relay
and an extra load relay.
|
 |
View Catalog Page
(PDF Format) Download
Manual (ZIP format)
< Click
Image to Enlarge (800 x 428) |
LED Digital 40 Series 50 Series
|
-
DC Current and Voltage
-
AC True RMS Current and Voltage
-
Frequency
-
Temperature - Thermocouple & RTD
-
High-intensity, .56" Red LED Display
-
Fits in DIN and NEMA cutouts
-
Screw terminals standard
-
Snap-in case - no tools required
-
Price
competitive |
 |
View Catalog Page
(PDF Format) Download
Manual (ZIP format)
< Click Image
to Enlarge (744 x 600) |
Solid
State Meter Relays Self Contained
X-Series
Models: 303X
(3.5") 503X (4.5") 603X (5.5")
|
-
UL Recognized with suffix "XU" (except Model
371-X)
-
1% accuracy in most ranges
-
Control independent of meter indication
-
Single and double setpoints
-
High input impedance
-
Fast response
-
Narrow temperature spans
-
Rectangular & stackable edgewise
models
-
Customized Scales available
-
On/Off, Alarm, Limit or Time Proportioning Output
available
Here are the controllers for your
tough jobs - applications where shock or vibration creates problems
for mechanical controllers. All control functions in the
LFE/api Compack IV controllers (X Series)
are provided through integrated circuits to operate independently
from the meter. The Compack controller continues to operate even if
the meter should become damaged or inoperative. This isolation of
control functions meets the need for controllers engineered to
provide "laboratory precision" on production machinery.
The Solid-State Compack IV
controller processes input signals from thermocouples, RTD, AC or DC
sources for control applications involving On/Off, Alarm, Limit,
Time Proportioning or cycling control modes.
|
 |
View Catalog Page
(PDF Format) Download
Manual (ZIP format)
< Click Image
to Enlarge (750 x 600) |
Solid
State Meter Relays Self Contained Edgewise
X-Series
Model: 371X
|
-
UL Recognized with suffix "XU" (except Model
371-X)
-
1% accuracy in most ranges
-
Control independent of meter indication
-
Single and double setpoints
-
High input impedance
-
Fast response
-
Narrow temperature spans
-
Rectangular and stackable edgewise models
-
Customized Scales available
-
On/Off, Alarm, Limit or Time Proportioning Output
available
Here are the controllers for your
tough jobs - applications where shock or vibration creates problems
for mechanical controllers. All control functions in the
LFE/api Compack IV controllers (X Series)
are provided through integrated circuits to operate independently
from the meter. The Compack controller continues to operate even if
the meter should become damaged or inoperative. This isolation of
control functions meets the need for controllers engineered to
provide "laboratory precision" on production machinery.
The Solid-State Compack IV
controller processes input signals from thermocouples, RTD, AC or DC
sources for control applications involving On/Off, Alarm, Limit,
Time Proportioning or cycling control
modes.
|
|
|